Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Med ; 16(5): 603-6, 1p following 606, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20383155

RESUMO

Esophageal cancer is increasing in frequency in the United States faster than any other cancer. Barrett's esophagus, an otherwise benign complication of esophageal reflux, affects approximately three million Americans and precedes almost all cases of esophageal cancer. If detected as high-grade dysplasia (HGD), most esophageal cancers can be prevented. Standard-of-care screening for dysplasia uses visual endoscopy and a prescribed pattern of biopsy. This procedure, in which a tiny fraction of the affected tissue is selected for pathological examination, has a low probability of detection because dysplasia is highly focal and visually indistinguishable. We developed a system called endoscopic polarized scanning spectroscopy (EPSS), which performs rapid optical scanning and multispectral imaging of the entire esophageal surface and provides diagnoses in near real time. By detecting and mapping suspicious sites, guided biopsy of invisible, precancerous dysplasia becomes practicable. Here we report the development of EPSS and its application in several clinical cases, one of which merits special consideration.


Assuntos
Esôfago de Barrett/patologia , Neoplasias Esofágicas/patologia , Esofagoscopia/métodos , Esôfago/patologia , Refluxo Gastroesofágico/patologia , Esôfago de Barrett/complicações , Biópsia/métodos , Diagnóstico por Imagem/métodos , Endoscopia/métodos , Neoplasias Esofágicas/complicações , Refluxo Gastroesofágico/complicações , Humanos , Hiperplasia/patologia , Análise Espectral/métodos
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2009: 1997-2000, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19964032

RESUMO

This letter reports the development of an endoscopic polarized scanning spectroscopy (EPSS) instrument compatible with existing endoscopes. This instrument uses light scattering spectroscopy (LSS). In proof-of-principle studies using a single-point instrument, LSS has successfully demonstrated the ability to identify pre-cancer in the epithelial tissues of five different organs, including Barrett's esophagus (BE). The EPSS instrument can provide real time in vivo information on the location of otherwise invisible high grade dysplasia (HGD), a predictor of adenocarcinoma, and thus can serve as a guide for biopsy. It should greatly reduce the time and labor involved in performing screening and obtaining diagnoses, cause less patient discomfort and ensure that fewer biopsies are required for the reliable location of pre-cancerous lesions.


Assuntos
Esôfago de Barrett/patologia , Neoplasias Esofágicas/patologia , Esofagoscopia/métodos , Microscopia de Polarização/métodos , Biópsia , Diagnóstico por Imagem , Células Epiteliais/patologia , Desenho de Equipamento , Tecnologia de Fibra Óptica , Humanos , Microscopia de Polarização/instrumentação , Reprodutibilidade dos Testes , Análise Espectral/métodos
3.
Opt Lett ; 34(9): 1483-5, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19412313

RESUMO

Present techniques for prenatal diagnosis are invasive and present significant risks of fetal loss. Noninvasive prenatal diagnosis utilizing fetal nucleated red blood cells (fNRBC) circulating in maternal peripheral blood has received attention, since it poses no risk to the fetus. However, because of the failure to find broadly applicable identifiers that can differentiate fetal from adult NRBC, reliable detection of viable fNRBC in amounts sufficient for clinical use remains a challenge. In this Letter we show that fNRBC light-scattering spectroscopic signatures may lead to a clinically useful method of minimally invasive prenatal genetic testing.


Assuntos
Eritrócitos/citologia , Feto/citologia , Luz , Diagnóstico Pré-Natal/métodos , Espalhamento de Radiação , Análise Espectral/métodos , Adulto , Eritroblastos/citologia , Feminino , Humanos , Gravidez
4.
Appl Opt ; 46(10): 1760-9, 2007 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-17356619

RESUMO

We have developed a novel optical method for observing submicrometer intracellular structures in living cells, which is called confocal light absorption and scattering spectroscopic (CLASS) microscopy. It combines confocal microscopy, a well-established high-resolution microscopic technique, with light-scattering spectroscopy. CLASS microscopy requires no exogenous labels and is capable of imaging and continuously monitoring individual viable cells, enabling the observation of cell and organelle functioning at scales of the order of 100 nm.


Assuntos
Aumento da Imagem/instrumentação , Microscopia Confocal/instrumentação , Análise Espectral/instrumentação , Tomografia de Coerência Óptica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Aumento da Imagem/métodos , Microscopia Confocal/métodos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Análise Espectral/métodos , Tomografia de Coerência Óptica/métodos
5.
Appl Opt ; 44(28): 5956-65, 2005 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-16231803

RESUMO

An easy and accurate assessment of the renal function is a critical requirement for detecting the initial functional decline of the kidney induced by acute or chronic renal disease. A method for measuring the glomerular filtration rate is developed with the accuracy of clearance techniques and the convenience of plasma creatinine. The renal function is measured in rats as the rate of clearance determined from time-resolved transcutaneous fluorescence measurements of a new fluorescent glomerular filtration agent. The agent has a large dose-safety coefficient and the same space distribution and clearance characteristics as iothalamate. This new approach is a convenient and accurate way to perform real-time measurements of the glomerular filtration rate to detect early kidney disease before the renal function becomes severely and irreversibly compromised.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Taxa de Filtração Glomerular/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Microscopia de Fluorescência/instrumentação , Espectrometria de Fluorescência/instrumentação , Animais , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Microscopia de Fluorescência/métodos , Ratos , Espectrometria de Fluorescência/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...